NaI(Tl) Scintillator
Engineering Overview

NaI(Tl) Scintillator

General Encapsulated NaI(Tl) Scintillator is a hermetically sealed cylindrical sodium iodide detector crystal for gamma-ray detection and spectroscopy. ATR Crystal supplies NaI(Tl) crystals in aluminum or stainless steel housings with K9 glass, quartz or sapphire windows, standard sizes from 25.4 x 25.4 mm to 127 x 127 mm and custom sizes up to 150 mm diameter x 400 mm height.

Encapsulated NaI(Tl) Scintillator for Gamma-Ray Detection

General Encapsulated NaI(Tl) Scintillator is a hermetically sealed thallium-doped sodium iodide scintillator used for gamma-ray detection, counting and spectroscopy. NaI(Tl) offers high light output, good energy resolution and strong compatibility with photomultiplier tubes.

Because NaI(Tl) is hygroscopic, reliable encapsulation is essential. ATR Crystal supplies cylindrical NaI(Tl) crystals in aluminum or stainless steel housings with K9 glass, quartz or sapphire optical windows. Face-entry and side-entry radiation configurations, flanges, mounting features and other mechanical modifications can be reviewed.

Standard cylindrical sizes are available, and custom sizes can be reviewed up to 150 mm diameter x 400 mm height according to crystal growth, polishing, encapsulation and performance requirements.

Design Options

Design ItemAvailable OptionNotes
Metal containerAluminum or stainless steelSelected according to weight, mechanical strength, environment and mounting requirement.
Optical windowK9 glass, quartz or sapphireWindow choice depends on optical coupling, mechanical strength and environmental requirement.
GeometryCylindrical encapsulated NaI(Tl)Common for PMT-coupled gamma-ray detection modules.
Custom mechanical featuresSpecial flanges, mounting fixtures or other modificationsProvide drawing for review.
Maximum crystal sizeDia. 150 mm x height 400 mmSubject to specification, encapsulation and performance review.

When to Choose Encapsulated NaI(Tl) Instead of Bare NaI(Tl)

NaI(Tl) crystal is highly hygroscopic, so a sealed scintillator package is normally recommended for real detector use. Encapsulation protects the crystal from moisture and allows the optical window, reflector and mechanical housing to be matched to the readout design.

If your request mentions a pure NaI crystal scintillator, please confirm whether a hermetically sealed NaI(Tl) scintillator is acceptable. In most gamma spectroscopy and radiation monitoring instruments, encapsulated NaI(Tl) is more reliable than a bare crystal unless the user has immediate dry-box integration capability. For material-level background, read the NaI(Tl) crystal selection guide.

Features of Encapsulated NaI(Tl)

  • PMT-compatible emissionThe emission spectrum of NaI(Tl) is well matched with many photomultiplier tubes.
  • High light outputNaI(Tl) is widely used where high scintillation light yield is required.
  • Good energy resolutionStandard encapsulated models list <=8.0% at 662 keV or better, depending on size and configuration.
  • Hermetic protectionAluminum or stainless steel housings protect the hygroscopic NaI(Tl) crystal.
  • Custom window choiceK9 glass, quartz or sapphire windows can be reviewed according to detector design.
  • Custom detector integrationNaI(Tl) crystals can be integrated with PMTs, housings and detector assemblies.

Typical Specification

ModelCrystal SizeEncapsulationEnergy Resolution, Cs-137
NaI-D25H25Dia. 25.4 x 25.4 mmAluminum housing with K9 glass window<=8.0% at 662 keV or better
NaI-D25H40Dia. 25.4 x 40.0 mmAluminum housing with K9 glass window<=8.0% at 662 keV or better
NaI-D40H40Dia. 40.0 x 40.0 mmAluminum housing with K9 glass window<=8.0% at 662 keV or better
NaI-D50H50Dia. 50.8 x 50.8 mmAluminum housing with K9 glass window<=8.0% at 662 keV or better
NaI-D63H63Dia. 63.5 x 63.5 mmAluminum housing with K9 glass window<=8.0% at 662 keV or better
NaI-D76H76Dia. 76.2 x 76.2 mmAluminum housing with K9 glass window<=8.0% at 662 keV or better
NaI-D127H127Dia. 127 x 127 mmAluminum housing with K9 glass window<=8.0% at 662 keV or better

Note: other sizes or specifications can be customized according to your requirements.

General NaI(Tl) vs. Related Encapsulated Scintillators

ProductBest FitMain AdvantageDesign Notes
General encapsulated NaI(Tl)Standard cylindrical gamma detector crystalsHigh light output and mature PMT readoutRequires hermetic encapsulation.
Square Type NaI(Tl)Rectangular detector arrays and close-packed layoutsBetter packing geometry for square/cuboid detectorsHousing and window position should match readout plan.
X-Ray Type NaI(Tl)Low-energy X-ray detectionThin crystal/window design for low-energy photonsWindow material and thickness are critical.
End Well NaI(Tl)Sample counting with well geometryHigh counting efficiency around small samplesWell size and sample geometry must be specified.
LaBr3(Ce) ScintillatorHigh-resolution gamma spectroscopyBetter energy resolution and fast timingHigher cost and intrinsic La-138 background should be considered.

NaI(Tl) RFQ Checklist

RFQ ItemInformation to Provide
ApplicationGamma spectroscopy, survey meter, counting system, environmental monitoring or detector module.
Crystal sizeDiameter, height, tolerance and preferred standard model if applicable.
EncapsulationAluminum or stainless housing, K9/quartz/sapphire window, flange and mounting features.
Performance targetEnergy resolution at Cs-137 662 keV, light output, uniformity and inspection requirement.
ReadoutPMT, SiPM, photodiode, optical coupling, cable and electronics interface.
Order informationQuantity, packaging, inspection report and delivery schedule.

Frequently Asked Questions

Why does NaI(Tl) need encapsulation?
NaI(Tl) is hygroscopic, so it must be sealed in a suitable housing with an optical window to protect the crystal from moisture.
What window materials are available?
Common options include K9 glass, quartz and sapphire. The choice depends on optical coupling, mechanical requirement and operating environment.
What energy resolution can standard NaI(Tl) models provide?
The listed standard models specify <=8.0% at Cs-137 662 keV or better, subject to final crystal size and detector configuration.
Can sizes be customized?
Yes. Other sizes and specifications can be reviewed, with maximum crystal size listed as 150 mm diameter x 400 mm height.

Online Quotation Request

Please provide your phone number and email address, and we'll get in touch with you as soon as possible.
Product Name
NaI(Tl) Scintillator
Expected price
Booking Quantity