ATR-P200 Plastic Scintillator
ATR-P200 is a fast plastic scintillator for particle counters and cosmic-ray detectors, with a reported 0.9 ns rise time and 2.4 ns decay time. Custom…
Explore productExplore products and technical resources
ATR Crystal supplies custom plastic scintillator sheets, plates, bars and panels for radiation detection and research. Review SP101 polystyrene scintillator for general-purpose components and SP102 thin plastic scintillator sheets for beta detection. For a quotation, send the dimensions, thickness, quantity, application, surface finish and readout requirements. Material grade, available sizes and finishing options are confirmed for the requested configuration.
Discuss your requirements
Compare product details, then send dimensions, quantity and application for quotation.
ATR-P200 is a fast plastic scintillator for particle counters and cosmic-ray detectors, with a reported 0.9 ns rise time and 2.4 ns decay time. Custom…
Explore product
SP101 Plastic Scintillator is a blue-emitting polystyrene-based plastic scintillator for gamma rays, X-rays and general ionizing radiation detection. ATR Crystal supplies custom SP101 plates, slices,…
Explore product
SP102 Plastic Scintillator is a thin polystyrene-based plastic scintillator designed for beta-ray measurement and charged-particle detection. ATR Crystal supplies custom SP102 sheets and panels, typically…
Explore product
SP121 Plastic Scintillator is an SP102 polystyrene-based scintillator coated with 4.5 mg/cm2 ZnS(Ag), designed for dual alpha and beta radiation measurement. The ZnS(Ag) coating detects…
Explore product
SP122 Plastic Scintillator is an SP101 polystyrene-based plastic scintillator coated with ZnS(Ag), designed for low-energy gamma-ray detection down to about 40 keV in suitable detector…
Explore product
SP123 is a ZnS(Ag)-coated alpha scintillator screen on a PMMA substrate for alpha probes, surface contamination meters and custom alpha detection panels. The ZnS(Ag) coating…
Explore product
SPM100 Light Guide is a cast PMMA optical guide used to transfer scintillation light from a plastic scintillator or crystal detector to a PMT, SiPM,…
Explore productReview the material, geometry and finishing details before sending your inquiry.
Start with your application
Review general-purpose polystyrene scintillator for drawing-defined panels and shaped components. Send dimensions, quantity and surface-finish requirements.
View SP101 Plastic ScintillatorReview thin plastic scintillator sheets for beta-ray measurement. Specify thickness, active area and any detector-window or mechanical-support requirements.
View SP102 Thin Scintillator SheetsCheck panel geometry, wrapping and readout requirements before requesting a quotation for a muon detector project.
Read the Muon Panel GuideSend dimensions, quantity and your application to sales@atrscintillator.com. Material availability and the requested finishing or assembly scope will be confirmed before quotation.
Selection guide
| Material or format | What to specify | Application to review |
|---|---|---|
| SP101 plates, bars and blocks | Dimensions, surface finish, optical requirements and quantity. | General radiation counters and research detector components. |
| SP102 thin sheets | Thickness, active area, target beta energy and mechanical support. | Plastic scintillator for beta detection and contamination monitoring. |
| Panels and strips | Layer layout, light collection, sensor arrangement and acceptance criteria. | Plastic scintillator for muon tomography and muon veto systems. |
| Large-area panels | Required material base, active dimensions and instrument performance criteria. | Plastic scintillator for radiation portal monitors; suitability requires review. |
| Light guides | Scintillator interface, sensor dimensions and coupling geometry. | Optical transfer between the scintillator and photosensor. |
Manufacturing support
For plastic scintillator tiles, plates or strips, send dimensions, tolerances, quantity and surface requirements. Manufacturing feasibility and the available size range will be confirmed before quotation.
Specify bare polished material, reflector wrapping or light-guide coupling as required. Include the sensor arrangement and any housing constraints so the supply scope can be reviewed.
For designs using plastic scintillator strips with WLS fibers, provide groove width, depth, spacing, fiber diameter and end geometry. Machining and fiber-installation availability must be confirmed for the requested design.
FAQ
Price depends on material grade, dimensions, quantity, machining, polishing and any wrapping or assembly requirements. Email sales@atrscintillator.com with your drawing or dimensions and specify whether you need bare material or additional finishing.
Provide the coverage area, layer layout, panel or strip dimensions, installation space and readout arrangement. Light-collection requirements and acceptance tests should be defined with the detector design.
SP102 can be reviewed for beta-ray and charged-particle measurement. Send thickness, active area, quantity, target beta-energy range if known, and any entrance-window or mechanical-support requirements.
SP101 is polystyrene-based. If your instrument specifies PVT, state that requirement explicitly; material suitability and supply availability must be confirmed before quotation.
State whether the inquiry covers machined scintillator only or also fiber installation, reflector wrapping and housing. ATR will review the requested scope and confirm which operations can be supplied.