How the calculator works
At sea level, roughly one cosmic-ray muon crosses each square centimeter of a horizontal surface every minute. The Particle Data Group gives this rule of thumb as I ≈ 1 cm⁻² min⁻¹ for horizontal detectors, with a mean muon energy at the ground of about 4 GeV. The calculator multiplies this flux by the panel area and then corrects for orientation, coincidence geometry and measuring time.
- Angular distribution: the muon intensity falls with zenith angle θ approximately as cos²θ. For a flat panel tilted by an angle α from horizontal, this gives a rate of (1 + cos²α) / 2 times the horizontal rate: 87.5% at 30°, 75% at 45° and 50% for a vertical panel.
- Two panels in coincidence: only muons that cross both panels are counted. The calculator integrates the cos²θ distribution numerically over the overlap of the two panels, which stays accurate even for small panels far apart. The share depends only on the ratio of distance to panel size: two 10 × 10 cm panels keep about 90% of the muons crossing the top panel at 1 cm apart, about 81% at 2 cm and about 33% at 10 cm. Far apart, the rate approaches (2/π) × L²W²/g² per minute at a flux of 1 cm⁻² min⁻¹.
- Detection efficiency: the geometric rate is multiplied by the efficiency you enter: ε for a single panel and ε₁ × ε₂ for a coincidence, assuming independent, constant efficiencies. Two panels at 90% each record 81% of the geometric coincidence rate.
- Statistics: muon counts follow Poisson statistics, so a measurement with N counts has a 1σ uncertainty of about √N. A relative statistical uncertainty of about 10% needs 100 counts; about 1% needs 10,000 counts. This is counting statistics only: it does not mean the predicted rate is accurate to 1%, because the local flux, the detection efficiency and the model approximations add their own errors.
- Energy deposit: most sea-level muons are close to minimum-ionizing and lose about 2 MeV per centimeter of plastic scintillator. A 10 mm panel therefore sees about 2 MeV from a vertical muon, and more from inclined tracks. This helps when setting a discriminator threshold above noise and low-energy gamma background.
Example
A horizontal 50 × 50 cm plastic scintillator panel at sea level counts about 2,500 muons per minute, or about 42 per second. Two such panels stacked 10 cm apart count about 2,000 coincidences per minute, because some inclined muons leave through the side before reaching the lower panel.
What the estimate does not include
- Location: the flux increases with altitude and is reduced by buildings, concrete floors and underground sites. If you know a local value, enter it in the flux field. The Particle Data Group also notes that recent measurements favor a vertical intensity 10 to 15% lower than the classic value.
- Detector response: light collection, photosensor response and threshold setting are not modeled; enter a measured or expected detection efficiency to account for them. The thickness field is used only for the energy-deposit estimate.
- Geometry: muons entering or leaving through the panel edges are ignored, and the coincidence mode assumes two identical horizontal panels aligned one above the other. Accidental coincidences are not included.
Plastic scintillator for muon detectors
Muon counters, cosmic-ray telescopes and veto panels usually use plastic scintillator because it is available in large, thin sheets at low cost and responds quickly. For large panels, light is often collected through a PMMA light guide or wavelength-shifting fibers; see our case studies for two delivered detectors. To choose a panel, read plastic scintillator panels for cosmic-ray muon detection, or go directly to HZ-200 fast plastic scintillator. For gamma-ray detectors, use the scintillator thickness calculator.
Reference
- Particle Data Group, Review of Particle Physics, Cosmic Rays (2022): muon angular distribution ∝ cos²θ, mean energy at the ground about 4 GeV, and I ≈ 1 cm⁻² min⁻¹ for horizontal detectors.